Aldes VentZone Series VZ Zoned Bath Exhaust Kits

American Aldes VentZone® Systems VZ Zoned Bath Exhaust Kits are the most advanced zoned central exhaust ventilation kits on the market. The combination of an ENERGY STAR rated MPVS150 ventilator and Zone Register Terminals (ZRT-1) provides powerful-yet-silent zone controlled exhaust ventilation from bathrooms that are in use.

VZ kits allow for the use of a quiet, high-efficiency fan, and they reduce the load that other central ventilation systems put on heating and cooling systems because they do not ventilate all bathrooms simultaneously – only the one in use. Each VZ kit can support 2-5 bathrooms, and an expansion kit is available for up to 3 additional bathrooms.

*** NOTE THE MPVS150 FAN IS PURCHASED SEPARATELY FROM THE ZRT KITS ***. 

model description usually ships price QTY
29010 Aldes Electronic Push-Button Timer Switch Control. Pre-set delay times: 15/30/60/120 minutes. 120 VAC, 60 Hz, 1/3 hp (7.2 Amps), 500 W Incandescent. Part 29010. 1 Day. In-stock $47.40
29011 Aldes Electronic Fan/Light Timer Switch Control. Independent Fan/Light Controls. Pre-set times: 20/40/60 minutes. 120 VAC, 60 Hz, 1/6 hp, 500 W Incandescent. Part 29011. 1 Day. In-stock $47.40
add to basket

real-time shipping quotes are available before checkout on your shopping cart page

 

*** NOTE THE MPVS150 FAN IS PURCHASED SEPARATELY FROM THE ZRT KITS (NOT INCLUDED). ONLY THE VZ-5 IS CURRENTLY SOLD WITH THE FAN INCLUDED ***

aldes VZ specs

aldes VentZone specs

Do you have questions about the products on this page?

Click on the ? image on the left or this link to ask us your questions!
#1 Q:   What are the wiring requirements for each bathroom and the central fan? How does the central fan handle multiple inputs if more than one bathroom switch is on? Thank you.
A:   Here is the link to the installation manual. Page 4 shows the wiring configurations. The same power source must power the fan and the terminals. There is a wire from the terminals to the fan to tell it to turn on: https://www.hvacquick.com/catalog_files/Aldes_VZ_VentZone_IOM.pdf

       Asked on 2021-02-22 by Doss
#2 Q:   Does each zone input of exhaust air have individual dampers so they dont all draw exhaust air when only one is in use?
A:   Correct. Each one has a damper and only the terminals in occupied (in-use) areas are open for exhaust.

       Asked on 2020-09-23 by Jim
#3 Q:   Is the unit installed in a remote location(i.e. attic) and vent pipes run to its location?
A:   Yes. The fan is installed remote. Insulated flex ducts/pipes are run to each intake grille.

       Asked on 2014-12-15 by John

Related Products